I-LY1-B80/1(S) I-SPD ye-Single-Pole exhumekayo

I-LY1-B80/1(S) I-SPD ye-Single-Pole exhumekayo

Incazelo emfushane:

Ikilasi IIkilasi IIUhlobo 1Uhlobo 2
Indawo Yokusetshenziswa: Amabhodi Okusabalalisa Okungaphansi
Indlela Yokuvikela: L-PE, N-PE
Izilinganiso Zokukhuphuka: Ku = 40 kA (8/20 μs)
I-IEC/EN/UL Isigaba: Ikilasi I+II / Uhlobo 1+2
Izinto Ezivikelayo: Amandla Aphezulu MOV
Ezezindlu: Idizayini Exhumekayo
Ukuthobela: IEC 61643-11:2011 EN 61643-11:2012


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Idatha Yezobuchwepheshe

I-IEC Electrical 75 150 275 320 385 440
I-Nominal AC Voltage (50/60Hz) Uo/Un 60v 120 V 230 V 230 V 230 V 400 V
I-Maximum Continuous Operating Voltage (AC) Uc 75v 150 V 275V 320 V 385v 440v
Ukukhipha Okuncane Kwamanje (8/20 μs) In 40 kA 40 kA 40 kA 40 kA 40 kA 40 kA
Ukukhipha Okuphezulu Kwamanje (8/20 μs) Iubuningi 80 kA 80 kA 80 kA 80 kA 80 kA 80 kA
Ukukhishwa Okunamandla Kwamanje (10/350 μs) Iimp 7kA
I-Voltage Protection Level Up 0.8 kV 1.2 kV 2 kv 2 kv 2 kv 2.2 kV
Isikhathi sokuphendula tA < 25 ns
I-Backup Fuse (ubukhulu) 125 A gL / gG
Isilinganiso Samanje Sesifunda Esifushane (AC) lI-SCCR 35 kA / 50 kA
I-TOV Imelana nama-5s UT 90V 180V 335V 335V 335V 580V
I-TOV 120min UT 115V 230V 440V 440V 440V 765V
  imodi Melana Melana Ukuhluleka Okuphephile Ukuhluleka Okuphephile Ukuhluleka Okuphephile Ukuhluleka Okuphephile
Mechanical & Environmental  
I-Operating Temperature Range Ta -40ºF ukuya +158ºF [-40ºC kuya +70ºC]
Ukuswakama Okusebenzayo Okuvumelekile RH 5%..95%
Ukucindezela komkhathi nokuphakama 80k Pa ... 106k Pa / -500 m.....2000 m
I-Terminal Screw Torque Mubuningi 39.9 Ibf ·in [4.5 Nm]
I-Conductor Cross Section (ubukhulu) 2 AWG (Eqinile, Eminyene) / 4 AWG (Eguquguqukayo)
  35 mm2 (Okuqinile, Okugxilile) / 25 mm2(Okuguquguqukayo)
Ukukhweza 35 mm DIN Rail, EN 60715
Izinga Lokuvikeleka IP 20 (eyakhelwe ngaphakathi)
Impahla Yezindlu I-Thermoplastic: I-Degree yokucima i-UL 94 V-0
Ukuvikelwa Okushisayo Yebo
Isimo Esisebenzayo / Inkomba Yephutha Okuluhlaza ok / Isici esibomvu
Oxhumana Nabo Abakude (RC)

I-RC Ukushintsha Ikhono

I-RC Conductor Cross Section (ubukhulu)

Ongakukhetha

I-AC: 250V / 0.5 A;DC: 250V / 0.1 A;125V / 0.2 A;75V / 0.5 A

16 AWG (Okuqinile) / 1.5 mm2(Okuqinile)

FAQ

1: Ingakanani i-DC SPD yakho elinganisele ukuphulwa kwebanga lomthamo?
A: Sinikeza i-DC SPD kusuka ku-20kA kuya ku-60kA, 500VDC, 600VDC, 800VDC, 1000VDC, 1200VDC, 1500VDC.

Q 2: Uyilawula kanjani ikhwalithi?
A: Okokuqala, yonke impahla eluhlaza sikhethe esezingeni eliphezulu.
Okwesibili, abasebenzi bethu abangochwepheshe nabanekhono banakekela yonke imininingwane ekusingatheni ukukhiqiza.
Okwesithathu, umnyango wethu wokulawula ikhwalithi unesibopho esikhethekile sokuhlola ikhwalithi kunqubo ngayinye.
Ekugcineni, umkhiqizo wethu ulandela ngokuqinile uhlelo lokulawula ikhwalithi ye-ISO9001, yonke imikhiqizo kufanele ihlolwe ngemuva kokukhiqizwa okuqediwe.

Q 3: Mayelana nesikhathi sokulethwa, kufanele ngilinde isikhathi esingakanani ngaphambi kokuthola i-oda lami?
IMP: Kuncike ku-oda lakho lokuthenga.Kungcono sixoxe ngokohlelo lwakho lwemininingwane.

Q 4: Ithini isikhathi sakho sokukhokha?
A: Samukela i-T/T, L/C, D/A, D/P, WESTERN UNION, PAYPAL, CASH.

Umbuzo 5: Yimaphi amazwe othumele kuwo?
A: Sesivele sithumela emazweni amaningi aseYurophu, Middle East, South America, Southeast Asia, njll.
Siyajabula ukubona ukuthi ngamasevisi ethu ochwepheshe nezisombululo, amakhasimende ethu athola amabhizinisi amaningi futhi abasebenzisi bokugcina banjalo
anelisekile.

Q 6: Ungangisiza ukuthi ngikhethe i-DC SPD efanelekile?
IMP: Impela, sicela usithumele uphenyo futhi usitshele isidingo sakho, sinethimba lochwepheshe elizokusekela ekukhetheni amamodeli.

Q 7: Ingabe uyayihlinzeka ngesevisi ye-OEM ne-ODM?
A: Yebo, sisekela i-OEM & ODM.Kwezinye izinto sine-MOQ.